{
  "@context": [
    "../context.jsonld",
    {
      "@base": "https://aird.idx.or.kr/packages/15138835_8/"
    }
  ],
  "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#schema",
  "@type": "csvw:Schema",
  "csvw:column": [
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=__row_uid__",
      "@type": "csvw:Column",
      "csvw:name": "__row_uid__",
      "csvw:datatype": "xsd:string",
      "csvw:required": true,
      "aird:columnIndex": 1
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%B8%A1%EC%A0%95%EC%9D%BC",
      "@type": "csvw:Column",
      "csvw:name": "측정일",
      "csvw:datatype": "xsd:dateTime",
      "csvw:required": true,
      "aird:columnIndex": 2,
      "csvw:titles": {
        "@value": "측정일",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 설비의 RS 선간전압이 측정된 날짜와 시각",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/DATE",
      "aird:observedDatatype": "날짜형(DATE)",
      "aird:observedMaxLength": 19,
      "aird:observedFormat": "YYYY-MM-DD HH24:MI:SS",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "다값",
      "skos:example": [
        {
          "@value": "2024-01-01 00:00:00",
          "@language": "ko"
        },
        {
          "@value": "2024-02-04 03:39:00",
          "@language": "ko"
        },
        {
          "@value": "2024-02-04 03:45:00",
          "@language": "ko"
        },
        {
          "@value": "2024-02-04 03:44:00",
          "@language": "ko"
        },
        {
          "@value": "2024-02-04 03:43:00",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%9E%88%ED%8A%B8%ED%8E%8C%ED%94%84%EA%B0%92_1",
      "@type": "csvw:Column",
      "csvw:name": "히트펌프값_1",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 3,
      "csvw:titles": {
        "@value": "히트펌프값_1",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "1번 히트펌프에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "384.926",
          "@language": "ko"
        },
        {
          "@value": "386.515",
          "@language": "ko"
        },
        {
          "@value": "383.883",
          "@language": "ko"
        },
        {
          "@value": "382.221",
          "@language": "ko"
        },
        {
          "@value": "383.52",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%9E%88%ED%8A%B8%ED%8E%8C%ED%94%84%EA%B0%92_2",
      "@type": "csvw:Column",
      "csvw:name": "히트펌프값_2",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 4,
      "csvw:titles": {
        "@value": "히트펌프값_2",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "2번 히트펌프에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "384.926",
          "@language": "ko"
        },
        {
          "@value": "386.515",
          "@language": "ko"
        },
        {
          "@value": "383.883",
          "@language": "ko"
        },
        {
          "@value": "383.52",
          "@language": "ko"
        },
        {
          "@value": "383.715",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%9E%88%ED%8A%B8%ED%8E%8C%ED%94%84%EA%B0%92_3",
      "@type": "csvw:Column",
      "csvw:name": "히트펌프값_3",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 5,
      "csvw:titles": {
        "@value": "히트펌프값_3",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "3번 히트펌프에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "385.096",
          "@language": "ko"
        },
        {
          "@value": "385.129",
          "@language": "ko"
        },
        {
          "@value": "382.253",
          "@language": "ko"
        },
        {
          "@value": "383.161",
          "@language": "ko"
        },
        {
          "@value": "383.566",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%9E%88%ED%8A%B8%ED%8E%8C%ED%94%84%EA%B0%92_4",
      "@type": "csvw:Column",
      "csvw:name": "히트펌프값_4",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 6,
      "csvw:titles": {
        "@value": "히트펌프값_4",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "4번 히트펌프에 공급되는 전원의 R상과 S상 사이의 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "385.096",
          "@language": "ko"
        },
        {
          "@value": "385.129",
          "@language": "ko"
        },
        {
          "@value": "382.253",
          "@language": "ko"
        },
        {
          "@value": "381.708",
          "@language": "ko"
        },
        {
          "@value": "383.566",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%9E%88%ED%8A%B8%ED%8E%8C%ED%94%84%EA%B0%92_5",
      "@type": "csvw:Column",
      "csvw:name": "히트펌프값_5",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 7,
      "csvw:titles": {
        "@value": "히트펌프값_5",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "5번 히트펌프에 공급되는 전원의 R상과 S상 사이의 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "385.096",
          "@language": "ko"
        },
        {
          "@value": "385.336",
          "@language": "ko"
        },
        {
          "@value": "382.253",
          "@language": "ko"
        },
        {
          "@value": "382.086",
          "@language": "ko"
        },
        {
          "@value": "379.405",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EB%A9%94%EC%9D%B8%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "메인값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 8,
      "csvw:titles": {
        "@value": "메인값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "주 인입 전원(메인) 지점에서 측정한 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "392.113",
          "@language": "ko"
        },
        {
          "@value": "390.401",
          "@language": "ko"
        },
        {
          "@value": "387.954",
          "@language": "ko"
        },
        {
          "@value": "389.234",
          "@language": "ko"
        },
        {
          "@value": "387.742",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EB%A9%94%EC%9D%B8%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "온실메인값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 9,
      "csvw:titles": {
        "@value": "온실메인값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실에 인입되는 메인 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "386.132",
          "@language": "ko"
        },
        {
          "@value": "385.959",
          "@language": "ko"
        },
        {
          "@value": "384.161",
          "@language": "ko"
        },
        {
          "@value": "382.891",
          "@language": "ko"
        },
        {
          "@value": "383.927",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EB%86%8D%EC%95%BD%EC%82%B4%ED%8F%AC%EA%B8%B0%EA%B3%84%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "온실농약살포기계값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 10,
      "csvw:titles": {
        "@value": "온실농약살포기계값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 농약살포기계에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.273",
          "@language": "ko"
        },
        {
          "@value": "384.283",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "382.902",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EC%B2%9C%EC%9E%A5%EA%B0%9C%ED%8F%90%EB%AA%A8%ED%84%B0%EA%B0%92_1",
      "@type": "csvw:Column",
      "csvw:name": "온실천장개폐모터값_1",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 11,
      "csvw:titles": {
        "@value": "온실천장개폐모터값_1",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 천장개폐모터 1번에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.273",
          "@language": "ko"
        },
        {
          "@value": "384.283",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "382.733",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EC%B2%9C%EC%9E%A5%EA%B0%9C%ED%8F%90%EB%AA%A8%ED%84%B0%EA%B0%92_2",
      "@type": "csvw:Column",
      "csvw:name": "온실천장개폐모터값_2",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 12,
      "csvw:titles": {
        "@value": "온실천장개폐모터값_2",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 천장개폐모터 2번에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "384.283",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EC%88%98%ED%8F%89%EC%8A%A4%ED%81%AC%EB%A6%B0%EA%B0%9C%ED%8F%90%EA%B0%92_1",
      "@type": "csvw:Column",
      "csvw:name": "온실수평스크린개폐값_1",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 13,
      "csvw:titles": {
        "@value": "온실수평스크린개폐값_1",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 수평스크린 개폐 장치 1번에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "384.283",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%98%A8%EC%8B%A4%EC%88%98%ED%8F%89%EC%8A%A4%ED%81%AC%EB%A6%B0%EA%B0%9C%ED%8F%90%EA%B0%92_2",
      "@type": "csvw:Column",
      "csvw:name": "온실수평스크린개폐값_2",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 14,
      "csvw:titles": {
        "@value": "온실수평스크린개폐값_2",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "온실 수평스크린 개폐 장치 2번에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "381.505",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%9C%A0%EB%8F%99%ED%8C%AC%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "유동팬값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 15,
      "csvw:titles": {
        "@value": "유동팬값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "유동팬에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.385",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "381.505",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%9C%A0%ED%99%A9%ED%9B%88%EC%A6%9D%EA%B8%B0%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "유황훈증기값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 16,
      "csvw:titles": {
        "@value": "유황훈증기값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "유황훈증기에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "382.611",
          "@language": "ko"
        },
        {
          "@value": "382.58",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%96%91%EC%95%A1%ED%9A%8C%EC%88%98%ED%8E%8C%ED%94%84%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "양액회수펌프값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 17,
      "csvw:titles": {
        "@value": "양액회수펌프값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "양액 회수 펌프에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:unitLabel": "회",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "384.35",
          "@language": "ko"
        },
        {
          "@value": "381.671",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EA%B3%B5%EC%A1%B0%EC%8B%9C%EC%8A%A4%ED%85%9C%EA%B0%92_1",
      "@type": "csvw:Column",
      "csvw:name": "공조시스템값_1",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 18,
      "csvw:titles": {
        "@value": "공조시스템값_1",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "1번 공조시스템에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "381.018",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "384.35",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EA%B3%B5%EC%A1%B0%EC%8B%9C%EC%8A%A4%ED%85%9C%EA%B0%92_2",
      "@type": "csvw:Column",
      "csvw:name": "공조시스템값_2",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 19,
      "csvw:titles": {
        "@value": "공조시스템값_2",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "2번 공조시스템에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "382.58",
          "@language": "ko"
        },
        {
          "@value": "381.212",
          "@language": "ko"
        },
        {
          "@value": "382.619",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EA%B3%B5%EC%A1%B0%EC%8B%9C%EC%8A%A4%ED%85%9C%EC%88%9C%ED%99%98%ED%8E%8C%ED%94%84%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "공조시스템순환펌프값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 20,
      "csvw:titles": {
        "@value": "공조시스템순환펌프값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "공조시스템 순환펌프에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "382.619",
          "@language": "ko"
        },
        {
          "@value": "382.611",
          "@language": "ko"
        },
        {
          "@value": "384.35",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%ED%8A%9C%EB%B8%8C%EB%A0%88%EC%9D%BC%EC%88%9C%ED%99%98%ED%8E%8C%ED%94%84%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "튜브레일순환펌프값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 21,
      "csvw:titles": {
        "@value": "튜브레일순환펌프값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "튜브레일 순환펌프에 공급되는 3상 전원의 R상과 S상 간 선간전압 측정값",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "382.619",
          "@language": "ko"
        },
        {
          "@value": "382.62",
          "@language": "ko"
        },
        {
          "@value": "380.154",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%96%91%EC%95%A1%EA%B8%B0%EA%B3%84%EA%B0%92",
      "@type": "csvw:Column",
      "csvw:name": "양액기계값",
      "csvw:datatype": "xsd:decimal",
      "csvw:required": true,
      "aird:columnIndex": 22,
      "csvw:titles": {
        "@value": "양액기계값",
        "@language": "ko"
      },
      "dct:description": {
        "@value": "양액기계(양액 공급 장치)에 공급되는 전원의 R상과 S상 간 선간전압",
        "@language": "ko"
      },
      "aird:descriptionKind": "http://vocab.datahub.kr/def/aird/description-kind/DEFINITION",
      "aird:semanticType": "http://vocab.datahub.kr/def/aird/semantic-type/NUMERIC",
      "aird:observedDatatype": "숫자형(NUMBER)",
      "aird:observedMaxLength": 7,
      "aird:observedFormat": "9(7).9(3)",
      "aird:observedMissingRate": 0.0,
      "aird:observedDistribution": "고카디널리티",
      "skos:example": [
        {
          "@value": "382.416",
          "@language": "ko"
        },
        {
          "@value": "382.152",
          "@language": "ko"
        },
        {
          "@value": "382.619",
          "@language": "ko"
        },
        {
          "@value": "381.018",
          "@language": "ko"
        },
        {
          "@value": "381.438",
          "@language": "ko"
        }
      ]
    },
    {
      "@id": "https://aird.idx.or.kr/data/15138835_8/dist/sha256:3829be679d678e71668e91dffa8b554dd30c5df843ed7da1dbe91c12d6fa99bc#col=%EC%A0%95%EC%A0%9C_%EC%B8%A1%EC%A0%95%EC%9D%BC",
      "@type": "csvw:Column",
      "csvw:name": "정제_측정일",
      "csvw:datatype": "xsd:dateTime",
      "csvw:required": true,
      "aird:columnIndex": 23
    }
  ]
}
